UV Exposure Test
At least two 457mm * 1219mm specimens were prepared and exposed to UV sun lamps for 10 +/- 0.2 hours each day for 21 days (210 hours +/- 1 hour) as per Section 4.1.2 of ICC-ES AC 38. The lamps and enclosure were adjusted to maintain the specimens at a product temperature of between 57.2°C and 60°C. Visual examination of the specimens was conducted after UV exposure for any evidence of surface or structural changes. Prepared specimens were then subjected to Accelerated Aging.
Test Results: Ultraviolet Light, No Cracking, Pass
Next> Accelerated Aging